Autoclave de paillasse à vide pulsé, classe B (ST-B60PV / ST-B80PV)

ST-B60PV · ST-B80PV

Benchtop Pulse Vacuum Autoclave, Class B

Benchtop Class B pulse-vacuum autoclave (60 or 80 L), steam, 121/134 °C, 304 stainless chamber, 14 L water tank, low noise (≤65 dB).

Request a quote

Category: Laboratory equipment · Autoclaves & steam sterilisers

Specifications by model

CharacteristicST-B60PVST-B80PV
Capacity60 L80 L
Chamber (Ø×H) (mm)Ø391×521Ø391×671
TypePulsed vacuum (class B)Pulsed vacuum (class B)
Operating temperature121 / 134 °C121 / 134 °C
Design pressure-0,1 / 0,3 MPa-0,1 / 0,3 MPa
Water tank14 L14 L
Chamber materialInox 304Inox 304
Noise level≤65 dB≤65 dB
Power consumption5,8 kW6,2 kW
Power supply220/110 V, 50/60 Hz220/110 V, 50/60 Hz

Full description

The ST-B60/80PV series is a Type B sterilizer that uses steam as the medium. The non-liquid program is suitable for the sterilization of surgical instruments, etc. 304 stainless steel chamber, 14 L water tank, design pressure -0.1/0.3 MPa, working temperatures 121/134 °C. Features: Display:The LCD touch screen can display temperature, pressure, time, operating status, fault alarm, equipment operation curve Multi-point Temperature Control Technology The insulation function can be set as needed to achieve liquid culture medium sterilization, culture medium dissolution-insulation function. With over-temperature automatic protection device, anti-dry burning protection device, over-pressure automatic release device, over-current protection device, electronic circuit safety device Self-calibration Function Independently Installed Pressure Sensors Automatic water injection, automatic drainage 0.1~0.5MPa, Accuracy level: 1.6 Manually removable filter, easy to clean, more user-friendly B&D testing, Vacuum testing Program, Medium Sterilization & Dissolution The sterilizer chamber is spacious and can accommodate multiple devices for efficient sterilization. Suitable for batch sterilization of medical equipment, laboratory instruments, etc. Digital control panel with precise temperature and time control ensures accuracy and consistency of the sterilization process. The pressure gauge monitors the pressure inside the equipment in real time to guarantee the safety and effectiveness of the sterilization process. Ventilated grid design at the back of the sterilizer enhances the heat dissipation performance of the equipment and ensures the stability of long-time operation. Built-in basket racks make it easy to accommodate instruments of different sizes for sterilization, while optimizing the use of sterilization space.

In the same family