| Groupe | Characteristic | Value |
|---|---|---|
| Specifications | ||
| Voltage DC | Accuracy 1 | ±(0.09% + 2) |
| Voltage DC | Max. resolution | 0.1 mV |
| Voltage DC | Maximum | 1000 V |
| Voltage AC | Accuracy 1 | ±(1.0% + 3) |
| Voltage AC | Max. resolution | 0.1 mV |
| Voltage AC | Maximum | 1000 V |
| Current DC | Accuracy 1 | ±(1.0% + 3) |
| Current DC | Max. resolution | 0.01 mA |
| Current DC | Maximum | 10 A |
| Current AC | Accuracy 1 | ±(1.5% + 3) |
| Current AC | Max. resolution | 0.01 mA |
| Current AC | Maximum | 10 A |
| Resistance | Accuracy 1 | ±(0.9% + 1) |
| Resistance | Max. resolution | 0.1 Ω |
| Resistance | Maximum | 50 MΩ |
| Capacitance | Accuracy 1 | ±(1.2% + 2) |
| Capacitance | Max. resolution | 1 nF |
| Capacitance | Maximum | 10,000 µF |
| Frequency | Accuracy 1 | ±(0.1% + 1) |
| Frequency | Max. resolution | 0.01 Hz |
| Frequency | Maximum | 100 kHz |
| Temperature | Accuracy 1 | ±(1.0% + 10) |
| Temperature | Max. resolution | 0.1°C |
| Temperature | Range | -40°C / 400°C |
| 1. Accuracies are best accuracies for each function | ||
| Environmental Specifications | ||
| Operating temperature | -10°C to +50°C | |
| Storage temperature | -30°C to +60°C | |
| Humidity (without condensation) | 0% - 90% (0°C - 35°C) 0% - 70% (35°C -50°C) | |
| Safety Specifications | ||
| Overvoltage category | EN 61010-1 to 1000 V CAT III EN 61010-1 to 600 V CAT IV | |
| Agency approvals | UL, CSA, TÜV listed and VDE Pending | |
| Mechanical and General Specifications | ||
| Size | 43 x 90 x 185 mm | |
| Weight | 420 g | |
| Warranty | Lifetime | |
| Battery life | Alkaline ~200 hours typical, without backlight |