Manomètre différentiel TMC13 à soufflet

TEMPSENS · TMC13

Bellow Type Differential Pressure Gauge

Temperature range: 200°C max.

Category: Industrial sensors · Differential pressure gauges

Specifications by model

CharacteristicValue
GeneralGeneral
Tolerance±2.5% of full scale
Ambient temperature-40…+65°C [without dampening liquid] -20…+65°C [with dampening liquid]
Operating temperature200°C max.
Static pressure limits4 bar upto 0.4 bar 25 bar upto 2.5 bar 40 bar upto 16 bar
Standard versionStandard version
Dial diameterDN150
Span100 mbar…0...16 bar
MountingDirect, bottom connection
Process connection1/2" NPT (F) x 2 Nos.
Ingress protection ratingIP 65
VersionDry / Dry but fillable
MaterialMaterial of construction
Sensing elementDiaphragm
Case and bezel materialAISI 304 SS (Bayonet type)
BellowsAISI 316L SS
ChamberAISI 304 SS
FastenerAISI 304 SS
MovementAISI 304 SS
DialAluminium, black graduation on white background
PointerMicro-zero adjustable, aluminium, black powder coated
SealsNeoprene
WindowShatterproof safety glass
Filled versionsFilled versions
GlycerineGlycerine
Tolerance±4.0% of full scale
Damping fluidGlycerin 99.7%
Electric contact versionElectric contact version
Tolerance±4.0% of full scale
WindowPolycarbonate dome
Contact1NO; Make contact
Damping fluidDielectric oil [optional]
Temperature effectWhen temperature of the measuring system deviates from reference temperature (+20°C) : max error ±0.4% / 10K of true scale value.

Full description

• All SS measuring system • External Zero adjustment • Electric contact version • Dry / liquid filled

In the same family