TEMPSENS · TMC15
Magnetic Differential Draft Pressure Gauge
Temperature range: 60°C max
Price on request
Details

TEMPSENS · TMC13
Temperature range: 200°C max.
Category: Industrial sensors · Differential pressure gauges
| Characteristic | Value |
|---|---|
| General | General |
| Tolerance | ±2.5% of full scale |
| Ambient temperature | -40…+65°C [without dampening liquid] -20…+65°C [with dampening liquid] |
| Operating temperature | 200°C max. |
| Static pressure limits | 4 bar upto 0.4 bar 25 bar upto 2.5 bar 40 bar upto 16 bar |
| Standard version | Standard version |
| Dial diameter | DN150 |
| Span | 100 mbar…0...16 bar |
| Mounting | Direct, bottom connection |
| Process connection | 1/2" NPT (F) x 2 Nos. |
| Ingress protection rating | IP 65 |
| Version | Dry / Dry but fillable |
| Material | Material of construction |
| Sensing element | Diaphragm |
| Case and bezel material | AISI 304 SS (Bayonet type) |
| Bellows | AISI 316L SS |
| Chamber | AISI 304 SS |
| Fastener | AISI 304 SS |
| Movement | AISI 304 SS |
| Dial | Aluminium, black graduation on white background |
| Pointer | Micro-zero adjustable, aluminium, black powder coated |
| Seals | Neoprene |
| Window | Shatterproof safety glass |
| Filled versions | Filled versions |
| Glycerine | Glycerine |
| Tolerance | ±4.0% of full scale |
| Damping fluid | Glycerin 99.7% |
| Electric contact version | Electric contact version |
| Tolerance | ±4.0% of full scale |
| Window | Polycarbonate dome |
| Contact | 1NO; Make contact |
| Damping fluid | Dielectric oil [optional] |
| Temperature effect | When temperature of the measuring system deviates from reference temperature (+20°C) : max error ±0.4% / 10K of true scale value. |

TEMPSENS · TMC15
Temperature range: 60°C max

TEMPSENS · TMC11
Temperature range: 200°C max.

TEMPSENS · TMC12
Temperature range: 10…150°C max.

TEMPSENS · TMC14-1
Temperature range: 200°C max.