Manomètre à membrane Schaffer TMC16-1

TEMPSENS · TMC16-1

Schaffer Diaphragm Pressure Gauge

Schaffer diaphragm pressure gauge, ±1.6% of full scale accuracy, IP 54, for corrosive media.

Request a quote

Category: Industrial sensors · Gauges with diaphragm seals

Specifications by model

CharacteristicValue
GeneralGeneral
DesignEN 837-3
Tolerance±1.6% of full scale
Ambient temperature-40…+65°C
Operating temperature100°C max.
Pressure limitsSteady pressure up to FS value Fluctuating pressure up to 90% of FS value
WeldsTIG argon arc welding
Standard versionStandard version
Dial diameterDN100 / DN150
Span-1...0...25 bar [Standard] / 60...600 mbar [Low pressure] 6...40 mbar [Very low pressure]
MountingDirect, bottom connection
Process connection½" NPT (M) / ½” BSP (M)
Ingress protection ratingIP 54
VersionDry
MaterialMaterial of construction
Sensing elementDiaphragm
Case and bezel materialAISI 304 SS (Bayonet type)
TopAISI 304 SS -Machined Flange
DiaphragmAISI 316 SS / Monel / Hastelloy C-276
BottomAISI 304 SS / AISI 316 SS / Monel Hastelloy C-276-Machined Flange
MovementCopper alloy
DialAluminium, black graduation on white background
PointerMicro-adjustable, aluminium, black powder coated
Gaskets, blow-off disc & filling plugNeoprene / NBR
WindowSheet glass / Shatterproof Safety Glass
OptionPTFE lining
Filled versionsFilled versions
GlycerineGlycerine
Tolerance2.5% of full scale
Operating temperature-20°C up to 65°C
Ranges≥ 600 mbar
Damping fluidGlycerin 99.7% / 80% / 60%
Ranges≥ 100 mbar
Damping fluidGlycerin + Water [20%+80%]
Temperature effectWhen temperature of the measuring system deviates from reference temperature (+20°C) : max error 0.4% / 10K of true scale value.

Full description

Schaffer type diaphragm pressure gauge: the diaphragm clamped between two flanges measures the pressure of viscous, laden or corrosive media that would clog a Bourdon tube. Features: Accuracy: ±1.6% of full scale. Ingress protection: IP 54. Ambient temperature : -40…+65°C Application areas: liquid and gaseous mediums, corrosive environments, oil and gas, chemical and petrochemical, food and beverages, nuclear power plants. Part Code: TMC16-1 Applications Areas Liquid & gaseous mediums Oil & Gas applications Chemical & Petrochemical Food & Beverages All SS measuring system Socket-case, direct welded Threaded / Flanged connection External zero adjustment

In the same family