Câble thermocouple T-301

TEMPSENS · T-301

Thermocouple Cable (T-301)

Thermocouple Cable (T-301) — Construction: PTFE — aluminium/polyester — PTFE, rated to 260 °C.

Request a quote

Category: Industrial sensors · Thermocouple & compensating cables

Specifications by model

Cable ordering codeWire typeAWG / SWG no.Number of strandsStrand dia. (mm)Cross-section area (mm²)Nominal bunched conductor dia. (mm)Cable formationNominal cable diameter, mm (flat)Nominal cable diameter (mm)Cable weight (approx.), kg/km
T301Solid24 AWG10.510.200.51Twisted-2.920.0
T302Multistrand7X32 AWG70.200.220.56Twisted-2.922.0
T303Multistrand7X30 AWG70.250.350.75Twisted-3.625.0
T304Solid22 SWG10.710.400.71Twisted-3.626.0
T305Multistrand7X32 SWG70.270.420.82Twisted-3.829.0
T306Solid20 AWG10.810.500.81Twisted-3.829.0
T307Multistrand7X29 AWG70.300.500.90Twisted-3.929.0
T308Multistrand16X32 AWG160.200.500.90Twisted-3.929.0
T309Multistrand7X28 AWG70.320.560.96Twisted-4.132.0
T310Multistrand7X27 AWG70.370.751.11Twisted-4.436.0
T311Multistrand24X32 AWG240.200.751.11Twisted-4.436.0
T312Solid18 AWG11.020.811.02Twisted-4.238.0
T313Multistrand7X26 AWG70.400.881.20Twisted-4.739.0
T314Solid17 AWG11.131.001.13Twisted-4.645.0
T315Multistrand14X29 AWG140.301.001.30Twisted-4.945.0
T316Multistrand32X32 AWG320.201.001.30Twisted-4.945.0
T317Multistrand7 X 27 SWG70.431.001.30Twisted-4.945.0
T318Multistrand3X22 SWG30.711.201.55Twisted-5.550.0
T319Multistrand40X36 SWG400.191.251.40Twisted-5.252.0
T320Solid16 AWG11.291.301.29Twisted-4.956.0
T321Multistrand19X29 AWG190.301.301.50Twisted-5.556.0
T322Multistrand19 X 28 AWG190.321.501.60Twisted-5.759.0
T323Multistrand21X29 AWG210.301.501.55Twisted-5.659.0
T324Multistrand7X24 AWG70.531.501.55Twisted-5.659.0
T325Multistrand48X36 SWG480.191.501.55Twisted-5.659.0

Full description

Thermocouple Cable (T-301). Features: Conductor: solid or multistrand, thermocouple, extension or compensating grade materials as per ASTM E230/77 and IEC 584-3. Insulation: PTFE insulation. Construction: twisted. Screening: aluminium/polyester shield with tinned copper drain wire. Outer jacket: PTFE sheathed. Operating temperature: 260 °C. Limit of error: according to ASTM E230/77 and IEC 584. Colour code: according to ANSI MC 96.1. Part Code: T-301 PTFE -ALMYLER-PTFE INSULATED -260°C

In the same family