TEMPSENS · EL50-HEx
Temperature range: 0°C….800°C
Category: Industrial sensors · Infrared pyrometers
| Characteristic | Value |
|---|---|
| Plage de température (Analog sub-range adjustable) | 0°C….800°C |
| Domaine spectral | 8…14 μm |
| Type de photodétecteur | Thermopile |
| Rapport distance / diamètre de visée | 2:1 15:1 (To be specified while ordering) |
| Émissivité | 0.1….1.2 adjustable |
| Temps de réponse | 60 msec adjustable up to 10 sec |
| Tolérance | ±1.5% of the measured value or 2°C whichever is greater (The sensor head must be at constant ambient temperature for a minimum of 15 minutes) |
| Répétabilité | 0.3% of reading in °C + 1°C |
| Sortie analogique | 0-20mA, 4-20mA, 0-10V, Thermocouple Type “K” or “J”(User selectable) |
| Sortie numérique | USB 2.0 RS-232/RS-485 interface card (Optional) *At a time only one digital output is possible |
| Température de fonctionnement | Electronic box up to 70°C Sensor head up to 180°C |
| Température de stockage | -20....60°C(Electronics & Zener), -20....180°C (Sensor Head) |
| Sortie relais | Relay Output with hysteresis 60V DC/42V AC RMS, 0.4A |
| Zener Barriers | FM Approval: 116-0118 UL Approval: 116-0139(cULus) IECEx Approval: IECEx BAS 09.0142 IECEx BAS 17.0091x |
| Environment Rating | Acc. to IEC 62529. Clamping carrier IP 20/housing IP 40 |
| Approved for | [Ex ia Ga] llC, [Ex ia Da] lllC, [Ex ia Ma] l, Ex ec llC T4 Gc |
| Paramètres réglables par logiciel | Emissivity, Response Time, Clear Time (Peak Picker),Analog Output, Analog Scale (Sub Range), Unit temperature (°C/°F), Communication mode), Record Feature Etc. |
| Adjustable Parameters and Features via Keypad | Emissivity, Relay, Setpoint, Hysteresis (Hyst), Analog Sub Range, Analog Output, Unit of temperature, Sensor address, Response Time, Clear Time(Peak Picker) etc. |
| Alimentation | 12V DC to 28 V DC with reverse polarity protection |
| Consommation | Max 2.5 watt |
| Installation | In zone 2, division 2 & in safe area |
| Isolation | Power supply, *Digital output, and Analog output are galvanically isolated against each other * Not applicable for USB 2.0 digital output |
| Humidité de fonctionnement | 10-95%, non-condensing conditions |
| Poids | 600g, 112.5mmx82.5mmx33mm(L x W x H) |