Manomètre à contacts électriques TMC06, boîtier dôme

TEMPSENS · TMC06

Electric Contact Pressure Gauge Dome Style

Electric Contact Pressure Gauge Dome Style — Accuracy: ±1.0% of full scale (gauge), ±4% of full scale (contact).

Request a quote

Category: Industrial sensors · Pressure gauges with contacts

Specifications by model

CharacteristicValue
GeneralGeneral
DesignEN 837-1
Tolerance±1.0% of full scale (Gauge) ±4% of full scale (Contact)
Ambient temperature-40…+65°C [without dampening liquid] -20…+65°C [with dampening liquid]
Operating temperature200°C max.
Pressure limitsSteady pressure up to FS value Fluctuating pressure up to 90% of FS value
WeldsTIG argon arc welding
Protection class as per EN 837-1S1
Standard versionStandard version
Dial diameterDN100 / DN150
Span-1...0...1,600 bar
MountingDirect, bottom connection
Process connection½" NPT (M) / ½" BSP (M)
Ingress protection ratingIP 65
VersionDry / Dry but fillable
ContactMake contact (1NO)
Electrical termination4 pin PG 13.5 connector
MaterialMaterial of construction
Sensing elementBourdon Tube [<100 bar : C - type , >100 bar : Helical]
Case and bezel materialAISI 304 SS [Bayonet type]
Bourdon tube and socketAISI 316L SS / Monel [Shank welded directly to case for rigidity in vibration field]
MovementAISI 304 SS
DialAluminium, black graduation on white background
PointerMicro-zero adjustable, aluminium, black powder coated
SealsNeoprene / NBR
WindowPolycarbonate dome
Filled versionsFilled versions
Tolerance±2.0% of full scale
Seals, safety disc and filling plugNBR / Viton
Damping fluidDielectric oil
Temperature effectWhen temperature of the measuring system deviates from reference temperature (+20C): max ±0.4% / 10K of full scale value.

Full description

Electric Contact Pressure Gauge Dome Style. Features: Accuracy: ±1.0% of full scale (gauge), ±4% of full scale (contact). Ingress protection: IP 65. Ambient temperature : -40…+65°C[without dampening liquid], -20…+65°C [with dampening liquid] Application areas: Pumps & motor controls Water treatment plants. Hydraulics and pneumatics. Chemicals and petrochemicals. Pharmaceutical industries. HVAC & compressor industries Part Code: TMC06 Applications Areas Hydraulic & pneumatics Chemical & petrochemicals Refrigeration All SS measuring system Socket-case, direct welded CE marked contacts Liquid filled versions