TEMPSENS · TMC07
Electric Contact Pressure Gauge Heightened Case
Electric Contact Pressure Gauge Heightened Case — Accuracy: ±1.0% of full scale (gauge), ±4% of full scale (contact).
Price on request
Details

TEMPSENS · TMC06
Electric Contact Pressure Gauge Dome Style — Accuracy: ±1.0% of full scale (gauge), ±4% of full scale (contact).
Category: Industrial sensors · Pressure gauges with contacts
| Characteristic | Value |
|---|---|
| General | General |
| Design | EN 837-1 |
| Tolerance | ±1.0% of full scale (Gauge) ±4% of full scale (Contact) |
| Ambient temperature | -40…+65°C [without dampening liquid] -20…+65°C [with dampening liquid] |
| Operating temperature | 200°C max. |
| Pressure limits | Steady pressure up to FS value Fluctuating pressure up to 90% of FS value |
| Welds | TIG argon arc welding |
| Protection class as per EN 837-1 | S1 |
| Standard version | Standard version |
| Dial diameter | DN100 / DN150 |
| Span | -1...0...1,600 bar |
| Mounting | Direct, bottom connection |
| Process connection | ½" NPT (M) / ½" BSP (M) |
| Ingress protection rating | IP 65 |
| Version | Dry / Dry but fillable |
| Contact | Make contact (1NO) |
| Electrical termination | 4 pin PG 13.5 connector |
| Material | Material of construction |
| Sensing element | Bourdon Tube [<100 bar : C - type , >100 bar : Helical] |
| Case and bezel material | AISI 304 SS [Bayonet type] |
| Bourdon tube and socket | AISI 316L SS / Monel [Shank welded directly to case for rigidity in vibration field] |
| Movement | AISI 304 SS |
| Dial | Aluminium, black graduation on white background |
| Pointer | Micro-zero adjustable, aluminium, black powder coated |
| Seals | Neoprene / NBR |
| Window | Polycarbonate dome |
| Filled versions | Filled versions |
| Tolerance | ±2.0% of full scale |
| Seals, safety disc and filling plug | NBR / Viton |
| Damping fluid | Dielectric oil |
| Temperature effect | When temperature of the measuring system deviates from reference temperature (+20C): max ±0.4% / 10K of full scale value. |

TEMPSENS · TMC07
Electric Contact Pressure Gauge Heightened Case — Accuracy: ±1.0% of full scale (gauge), ±4% of full scale (contact).

CITEC · 807-01
Polycarbonate dome

CITEC · 807-03
All stainless steel case

CITEC · 807-04
Measuring range from -1 to 25 bar