Manomètre de sécurité TMC04, boîtier phénolique

TEMPSENS · TMC04

Phenolic Case Safety Pressure Gauge

Temperature range: 300°C max.

Category: Industrial sensors · Specific pressure gauges

Specifications by model

CharacteristicValue
GénéralitésGeneral
ConceptionASME B40.100
ToléranceGrade 2A (± 0.5% of full scale)
Température ambiante-40…+65°C [without dampening liquid] -40…+65°C [with dampening liquid filled silicon oil]
Température de service300°C max.
Limites de pressionSteady pressure up to FS value Fluctuating pressure up to 90% of FS value Short time 130% of FS value for range up to 1500 PSI Short time 115% of FS value for range above 1500 PSI
SouduresTIG argon arc welding
Version standardStandard Version
Diamètre du cadran4.5" / 115mm
Étendue-15 - 0 - 23,200 PSI
MontageDirect Bottom
Raccord process¼" NPT (M) / ½" NPT (M)
Indice de protectionIP 65
ExécutionDry / Dry but fillable
MatériauMaterial of construction
Élément sensibleBourdon Tube [<100 bar : C - type , >100 bar : Helical]
Matériau du boîtier et de la lunettePhenolic [Screwed type]
Tube de Bourdon et embaseAISI 316L SS / Monel
MécanismeAISI 304 SS
CadranAluminum, black graduation on white background
Pointer Gaskets & filling plugNeoprene / NBR
Blow off discPP
HublotShatterproof safety glass
Versions rempliesFilled versions
GlycérineGlycerin
Liquide amortisseurGlycerin 99.7% / 80% / 60% [Service temperature -20°C up to 65°C]
Huile siliconeSilicon Oil
JointsNBR / Viton
Liquide amortisseurSilicon oil DC 200 [Service temperature -40°C up to 150°C]
Effet de la températureWhen temperature of the measuring system deviates from reference temperature (+20°C): max ±0.4% / 10K of full scale value.

Full description

Tempsens Phenolic Case Safety Pressure Gauge is ideal for applications where pressure indication must be supported with added operator protection. These gauges will perform in environments where process fluctuation, harsh media, or safety risk exist. For plant personnel, the gauge contributes to safer monitoring of process pressures while providing increased confidence during routine pressure checks. • Turret design • Follows ASME B40.100 • Accuracy as per Grade 2A / ±0.5% • Dry / Fillable / Liquid filled