Manomètre sanitaire TMC10

TEMPSENS · TMC10

Sanitory Pressure Gauge

Sanitory Pressure Gauge — Accuracy: ±1.6% of full scale.

Request a quote

Category: Industrial sensors · Specific pressure gauges

Specifications by model

CharacteristicValue
GeneralGeneral
DesignEN 837-3
Tolerance±1.6% of full scale
Ambient temperature-40…+65°C [without dampening liquid] -20…+65°C [with dampening liquid]
Operating temperature10…150°C max.
Pressure limitsSteady pressure up to FS value Fluctuating pressure up to 90% of FS value Short time 1.3 x FS value for range up to 100 bar Short time 1.15 x FS value for range above 100 bar
WeldsTIG argon arc welding
Standard versionStandard version
Dial diameterDN50 / DN63 / DN100
Span-1…40 bar
MountingDirect, bottom connection
Process connection1½" Sanitary connection
Seal filling fluidGlycerine [10°C to 150°C]
Ingress protection ratingIP 65
VersionDry / Dry but fillable
MaterialMaterial of construction
Sensing elementDiaphragm
Case and bezel materialAISI 304 SS [Bayonet type]
Diaphragm, Bourdon tube & shankAISI 316L SS
MovementAISI 304 SS
DialAluminium, black graduation on white background
PointerFixed, aluminium, black powder coated
SealsNeoprene
WindowPlexiglass
Filled versionsFilled versions
GlycerineGlycerine
WindowPlexiglass
Damping fluidGlycerin 99.7%
Temperature effectWhen temperature of the measuring system deviates from reference temperature (+20°C) : max error ±0.4% / 10K of true scale value.

Full description

Sanitory Pressure Gauge. Features: Accuracy: ±1.6% of full scale. Ingress protection: IP 65. Ambient temperature : -40…+65°C [without dampening liquid], -20…+65°C [with dampening liquid] Application areas: Sanitary, food & beverages Pharmaceuticals and paints. Prevents the bacterial and fungal build-up that contaminates the process. Part Code: TMC10 Applications Areas Pharmaceutical & paints Bacterial & fungal accumulates which contaminates the process Integrated gauge seal assembly Reduced vibration/pulsation Laser welded diaphragm